Custom Engeneering s'print Manuel d'utilisateur Page 18

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 51
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 17
1. INSTALLATION AND USE
71-
DPT100-B
* SETUP DEFAULT *
HEAD TEMP. [°C] = 22.5
BATT TEMP. [°C] = 25.0
HEAD VOLT [V] = 6.3
Interface :Infrared
Baud Rate : 9600 bps
Data length : 8 bits/chr
Parity : None
Handshaking : Xon/Xoff
Autofeed : CR disabled
Battery : 1600 mAh
Standby : 5 MIN
Print Density : 0
[PUSH] ENTER SET-UP
[FAST PUSH] EXIT SET-UP
The printers configurable parameters are:
Interface: RS232
D
, Infrared
(7)
.
Baud Rate: 38400, 19200, 9600
D
, 4800, 2400, 1200, 600.
Data length: 7, 8
D
bits/car.
Parity: None
D
, even or odd.
Handshaking: XON/XOFF
D
or Hardware
(8)
.
Autofeed: CR deactivated
D
or CR activated.
Battery: 600 mAh, 800 mAh, 1000 mAh, 1200 mAh
D
, 1400 mAh,
1600 mAh, Alkaline
(9)
.
Standby: 30 sec, 1min, 2 min, 5min
D
, 10 min, 20 min
(10)
.
Print density: -2, -1, 0
D
, +1, +2.
Please note: the parameters marked with the symbol
D
represent the default
values.
(7)
Note
If the Interface parameter is set in infrared and flow control is required, any time a
transmission is effected a time break of one time and a half the byte transmission
is needed (for example 1.5 msec at 9600 bps). The reason is for Half Duplex type
of infrared line communication. As a result the Busy condition check must be waited
when transmitting data to the printer.
If said condition would slow down print-out, it is alternatively possible to transmit the
bytes to be printed in fixed length blocks (for example 16 bytes at a time) and to
wait for the necessary time to receive a likely XON/XOFF.
(Fig.1.9)
Vue de la page 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 50 51

Commentaires sur ces manuels

Pas de commentaire